Kentec Sigma CP Sounder PCB Boxed c/w 5.25A PSU K04400M2

SKU: K04400M2
Log in to see pricePrices are shown to logged-in customers. Log in, or create a free account, to see the price and order.
Key featuresTwo wire serial connectionUp to 7 sounder boards per system230V AC or 24V DC powered versionsZoned, 2-stage or common alarmAll outputs monitored for open and short circuit faultsIndividual open and short circuit fault indicators

Sigma CP Conventional Sounder Controller Units

The Sigma CP Sounder Board is compatible with all Sigma CP control panels which have operating software version V3.0 or above. 

The board provides 8 additional sounder outputs which can be configured as zoned, 2-stage or common alarm. 

All sounder outputs are open and short circuit monitored and any faults on the sounder outputs will be announced at the main fire alarm panel as a sounder fault. 

A class change input is provided which, when activated by a volt free contact closing, will switch all sounder outputs on. 

Mains powered units require only a two core data cable from the main control panel. 24V DC versions require an additional two cores from another 24V DC source which is suitably rated to supply the total sounder current. 230V versions have their own power supply which is rated to supply sounder loads up to 5.25 Amps. 

Up to 7 Sounder boards can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. Sounder boards may be connected to the Sigma CP serial bus in addition to Sigma CP ancillary boards and Sigma CP-R repeater panels. 

The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres. Once Sounder boards have been recognised by the main panel, a fault will be announced at the main panel if any become disconnected.

Features

  • Two wire serial connection 
  • Up to 7 sounder boards per system 
  • 230V AC or 24V DC powered versions 
  • Zoned, 2-stage or common alarm 
  • All outputs monitored for open and short circuit faults 
  • Individual open and short circuit fault indicators 
  • Fully monitored by main control panel 
  • Class change input facility 
  • Up to 8 outputs with 1A available from each
  • Can be connected to serial bus with Ancillary boards and repeaters 
  • Boxed units in enclosure to match Sigma CP control panels 
  • Power fault input for monitoring remote power supplies